Sbu Block Diagram; Signal Processing; A/D Conversion; White Level Correction - Ricoh B051 Service Manual

Ricoh mfp service manual
Table of Contents

Advertisement

IMAGE PROCESSING

6.6.2 SBU BLOCK DIAGRAM

O
R(B)
Analog Amplifier
E
O
G
Analog Amplifier
CCD
E
O
B(R)
Analog Amplifier
E
SBU

Signal Processing

1. Signal Amplification
• Odd-pixel and even-pixel RGB analog signals from the CCD are amplified.
2. Signal Composition
• The amplified signals are combined after A/D conversion.

A/D Conversion

• The analog signals (CCD output) are converted to 10-bit (1,024 gradations)
digital signals.

White Level Correction

• A white reference plate is scanned before the original is scanned.
• Data is updated before the original is scanned.
• The differences in the white level across the page, including irregularities in the
CCD and the optical parts across the main scan, are corrected.
Others
The SBU controller exchanges the R and B signals if originals are scanned through
the ARDF.
B051/B052
CÓPIA NÃO CONTROLADA
10 bit
A/D Converter
10 bit
A/D Converter
10 bit
A/D Converter
CÓPIA NÃO CONTROLADA
R
10 bit
Field
Memory
G
10 bit
SBU
Field
Controller
Memory
B
10 bit
BICU
6-24
8 bit
8 bit
ASIC
8 bit
B051D551.WMF