Bell_Core_Pattern1_Timing - Panasonic KX-UTG200 Administrator's Manual

Hide thumbs Also See for KX-UTG200:
Table of Contents

Advertisement

5.5.5 Tone Settings
Default Value

BELL_CORE_PATTERN1_TIMING

Value Format
Description
Value Range
Default Value
BELL_CORE_PATTERN2_TIMING
Value Format
Description
Value Range
Default Value
BELL_CORE_PATTERN3_TIMING
Value Format
Description
Value Range
Default Value
244
Administrator Guide
120,120,120,120,120,14400
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 1, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
2000,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 2, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
800,400,800,4000
Comma-separated Integer
Specifies the cadence, in milliseconds, of pattern ID 3, described in the
LSSGR, GR-506-CORE, "Signaling for Analog Interfaces" section 14,
using up to 8 whole numbers (on 1, off 1, on 2, off 2...) separated by
commas.
0–5000 (0: Infinite time)
Note
Avoid setting 1–50 for any of the values.
400,200,400,200,800,4000