IBM IntelliStation 6866 Hardware Maintenance Manual page 12

Table of Contents

Advertisement

Size
Weight
Environment
Heat Output
Electrical Input
Airflow
Acoustical Noise
Emission Values
4
IBM IntelliStation Type 6866: Hardware Maintenance Manual
Depth: 606 mm (23.9 inches)
Height: 440 mm (17.3 inches)
Width: 216 mm (8.5 inches)
Minimum configuration as shipped:
29.5 kg (65 lb)
Air temperature:
System on: 10 to 35 C
(50 to 95 F)
System off: 10 to 50 C
(50 to 122 F)
Humidity:
System on: 8% to 80%
System off: 8% to 80%
Maximum altitude: 3048 m (10,000 ft.)
Approximate heat output in BTUs per hour:
Minimum:
340 BTU/hr. (100 watts)
Maximum:
2385 BTU/hr. (700 watts)
Sine-wave input (47 to 63 Hz) required
Low range input voltage:
Minimum: 90 V AC
Maximum: 137 V AC
High range input voltage:
Minimum: 180 V AC
Maximum: 265 V AC
Input kVA (approximately):
Maximum (as shipped): 1.5kVA
Approximately 0.56 cubic meters/minute
(20 cubic feet/minute)
Average sound pressure levels:
At operator position:
- 41 dB operating
- 34 dB idle
At bystander position (1 meter):
- 34 dB operating
- 29 dB idle
Declared (upper limit) sound power levels:
- 5.3 bels operating
- 4.7 bels idle

Advertisement

Chapters

Table of Contents
loading

Table of Contents