QC 2235plus Theory of Operation Ver.1.0 Mar. 2004
20.2 Power distribution control at machine power up
20.2.1
Parts operated when the Power Switch is turned ON
• When the Power Switch is turned ON, the Control Board detects it and sends a control
signal to the DC Power Supply.
• The DC Power Supply then supplies 3.3V DC, 5V DC, 15V DC, and 24V DC to all PWBs
and options. It also turns ON the relays in the PWBs, supplying AC power to each of the
heater lamps.
SW1
24VDC
24VDC
PU1
5VDC
24VDC
15VDC
PWB-C
5VDC
24VDC
5VDC
24VDC
5VDC
24VDC
5VDC
3.3VDC
RY
2-93
DF-601
PWB-IC
5VDC
24VDC
5VDC
PWB-MC
5VDC
5VDC
5VDC
PWB-MFP
PWB-LED
H1,H2,H3
Other control
Control Panel
PWB-A
FS-601/FS-501
(OPTION)
AD-501
(OPTION)
PC-201
PC-101
(OPTION)
PC-401
(OPTION)
4036ma2194c0
Need help?
Do you have a question about the QC 2235 Plus and is the answer not in the manual?