Develop QC 2235 Plus Service Manual page 107

Develop qc 2235 plus service manual theory of operation
Table of Contents

Advertisement

QC 2235plus Theory of Operation Ver.1.0 Mar. 2004
16.3.3
Fusing temperature control
• The surface temperatures of the Heating Roller and Pressure Roller are detected using
thermistors and the corresponding Heater Lamps are turned ON or OFF as necessary to
maintain the set fusing temperature.
Temperature Control during the first-in-the-morning warm-up and setting using plain
paper
Warm-up Completed
Power Switch ON
195
190
180
160
150
130
100
Heating Roller
Thermistor
(TH1)
Fusing Pres-
sure Roller
Thermistor
(TH3)
0
[1]
In standby (first in the morning)
Heating Roller set temperature: 195 °C
[2]
In standby (first in the morning)
Heating Roller temperature: 190 °C
[3]
During a copy cycle
A. Warm-up
• Four different types of warm-up control are employed for varying the set temperature of
each roller, thereby preventing fusing performance from being degraded due to environ-
mental changes.
• Priority is given to the high humidity control.
Start Key ON
[1]
[2]
[3]
99 sec
[4]
[5]
2-77
[4]
[5]
In standby
Heating Roller temperature: 190 °C
Power Save
Fusing section
Canceled
4036ma2229c0