Panasonic KX-TA624 Installation Manual page 436

Advanced hybrid system
Hide thumbs Also See for KX-TA624:
Table of Contents

Advertisement

Step
Program Title
211
No Dial Disconnection
212
CO Line Duration Limit
213
Bell Off Detection
301
Call Barring – System Speed Dial
Boundary Class
309
Emergency Dial Number Set
310
Account Codes
311
Automatic Pause Insertion Codes
312
Call Barring – Extension Lock
400
CO Line Connected Assignment
402
Pulse Speed Selection
404
CO Line Group Assignment
414
Outside Line Mode
to
( Day / Night / Lunch )
416
417
Pause Time
421
CPC Detection for Outgoing Calls
423
CO Line Ringing Pattern Selection
424
Reverse (Polarity) Check
500
DISA Incoming Dialling Mode
Selection - Auto Attendant
501
DISA Built-in Auto Attendant
502
OGM Mode Selection
( KX-TA 62491 required )
503
FAX Connection
( KX-TA 62491 required )
504
DISA Delayed Answer Time
505
DISA Waiting Time after OGM
506
DISA Busy Mode
507
DISA Intercept Mode
Disconnect / Intercept
508
DISA Ring Time before Intercept
509
DISA Ring time After Intercept
510
DISA No Dial Mode
513
Cyclic Tone Detection
( OGM option KX-TA62491 required )
NEW
P
rogramming Steps
( with reference to the KX-T30810 / 61610 )
Feature Description
Call disconnects if 1
within 20 seconds of seizing a CO Line
Sets maximum CO call time (Enabled Prog 613)
Sets the wait time between bell signals from CO line
Assigns the call barring class for System Speed Dial
Numbers
Stored 'Emergency' telephone numbers override the
following : 'COS Level' / 'Account Code Modes' /
'Electronic Extension Lock'
Assigns Account Codes for 'Verify - All' mode
40 codes can be assigned as Pause Codes.
Pause [ duration prog. step 417 ] is inserted after the
code
COS level applied to Locked Extensions
Options : COS Levels 2 / 3 / 4 / 5 / Disabled
Defines connected CO's
Sets CO Line 'Pulse Speed'
Options : 10 / 20 pps
Trunk Group assignment of CO's
NORMAL : Follows programming steps 408 ~ 410
DIL
: Assigns one ext. to receive I/C CO call
(must be used if Call FWD is required)
DISA1
: The caller will hear a Tone or OGM
DISA2
: The caller will hear two different OGM
UCD
: Call will be rec'd via UCD function
Assigns the Host PBX pause time
Enables CPC detection during an outside call.
If CPC is detected, the system disconnects the line
( disconnection time Program Step 420 )
Incoming CO Line ringing pattern
Options : Single / Double / Triple Ring
Detects CO Line reversal
Without AA System accepts : Ext. / Access No.
With AA
System accepts : Ext. / Access / AA No.
Assigns Auto Attendant numbers '0 ~ 9'
to extension jacks
Mode 1 ~ 6 DISA or UCD functions can be used
to receive IC calls
Assigns an extension to receive FAX calls
when CNG is detected
Assigns delay in DISA answering a call
Options : 0 / 3 / 6 / 12 secs
Selects time the system waits for DTMF
or CNG tone after OGM played
Options : 0 / 5 / 10 / 15 secs
Sets DISA response to a dialled busy extensions
Options : Call waiting / Disconnect / play OGM 2
Sets DISA response to unanswered calls
Options : Disconnect / Intercept
Sets DISA Intercept time for unanswered calls
Options : 10 / 20 / 30 / 40 / 60 / 120secs
Sets the ring time at the Intercept destination
Options : 10 / 20 / 30 / 40 / 60 / 120secs
Selects action taken by DISA if no response is received
after OGM ( e.g. DTMF or CNG )
Options : Intercept / Disconnect
Sets the number of times Cyclic Tone has to be detected
before the system regards the call as complete
Options : Disable ( does not detect ) / 2 / 3 / 4 times
st
Digit is not dialled
Default
Enable
( disconnect )
10 mins
3 secs
Class 1
Locations
01 : 999 02 : 112
03 ~ 05 : Not stored
01 ~ 24 : Not stored
i.e. 01 : 1234
01 ~ 40 : Not Stored
i.e. 01 : 1234567
Disabled
CO 1 ~ 6 : Connected
10 pps
CO 1 : Trunk Group 1
through to
CO 6 : Trunk Group 6
NORMAL
1.5 secs
Disable
Double
Disabled
Without AA
0 ~ 9 : Not stored
i.e. 0 : Jack 01
Mode 1
All Jacks : Disabled
3 secs
5 secs
Disconnect
Intercept
20 secs
20 secs
DISA1 : Intercept
DISA2 : Intercept
4 times
( 5 of 6 )

Advertisement

Table of Contents
loading

Table of Contents