[204], [206]
[204] Call Duration Count Start Time
Assigns the start time of a conversation either immediately after an exchange line is seized
or after dialling. This corresponds to the length of the conversation displayed on the LCD
and printed on the printer (SMDR).
2
Default
!
• If reverse signal detection is enabled in program [424] "Reverse (Polarity) Circuit
!
Assignment", the system will automatically start the timer immediately after an external
party answers a call.
• Feature References
Section 3, Features
Polarity Reverse Detection, Station Message Detail Recording (SMDR)
[206] Dialling Start Time
Assigns the minimum length of the pause time the system waits before dialling after seizing
an exchange line.
2
Default
• Feature Reference
Section 3, Features
Outside Calling
4-28
System Programming
0
4
NEXT
(5/10/15/20/25/30/
35/40/45/50 sec after
dial/Instantly)
10 seconds after dialling
0
6
NEXT
(0/250/500/750/
1000/1250/1500 ms)
0 millisecond
4.2
System Programming
STORE
SELECT
STORE
SELECT
END
END