m) Mist filter
Removing the mist filter
1) When removing the mist filter[2], open the top cover, and then remove the right circle cover.
2) Removing the screw[1], and then remove the mist filter[2].
n) Right cover
Removing the right cover
1) When removing the right cover[3], open the top cover, and then remove the roll feed unit, right circle cover,
right upper cover, operation panel, mist filter, exhaust filter, and lower rear cover.
2) Remove the six screws[1] and hook[2], and then remove the right cover[3].
[1]
[3]
[2]
[2]
F-4-19
F-4-20