Adjustment And Setup Items; Adjustment Item List; Procedure After Replacing The Carriage Unit Or Multi Sensor - Canon iPF6100 Service Manual

Hide thumbs Also See for iPF6100:
Table of Contents

Advertisement

4.5 Adjustment and Setup Items

4.5.1 Adjustment Item List

The following adjustment procedures need to be performed when parts have been replaced or remove and then
reinstalled:
Adjustment item
Multi sensor recalibration
Adjusting wire roller
Head management sensor recalibration

4.5.2 Procedure after Replacing the Carriage Unit or Multi Sensor

a) Multi Sensor Recalibration
Since multi sensors have individual electrical specificity, the following are recalibrated at the factory, namely,
the optical axis of the sensor, the sensor gain for measuring the printhead height and sensor reproduction.
Accordingly, carry out the following adjustments in the service mode whenever replacing the carriage unit or
multi sensor.
- Service mode : SERVICE MODE > ADJUST > GAP CALIB.
- Service mode : SERVICE MODE > ADJUST > PRINT PATTERN > OPTICAL AXIS
Media type : Photo glossy paper
Media size : Media having a width equal toor larger then that of A2-size paper
The multi sensor reference plate must be replaced at the same time whenever the carriage or the multi sensor is
being replaced.
T-4-1
Adjustment timing
Multi sensor replacement/removal
Carriage unit replacement/removal
Wire guide replacement/removal
Carriage unit replacement/removal
Head management sensor replacement/
removal
Carriage unit replacement/removal
Chapter 4
0016-9220
0012-6486
4-69