Upon exiting, the next selections are set to the values which were
selected before this adjustment.
– Active Unit
– Operation Mode
3.2.5 – AFC Diagram
The following automatic selections are made when this tuning function is
activated:
– Active Unit = RX
– Operation mode = Continuous
The D/A converter range is from +1023 to –1024 and the voltage range
from 0.25v to 4.45 accurate to within 0,01v.
The value range of the error values is between –134 kHz and +134 kHz
accurate to within 0.1 kHz.
If the measurement is incomplete when <Esc> is used, an information
message is shown. The user can remove the information message with
<Y>, <N> or <Esc> key. The measurement will be terminated by using
<Y> key. The measurement will continue if <N> or <Esc> key is used.
Upon exiting, the next selections are set to the values which were
selected before this adjustment.
– Active Unit
– Operation mode
Also AFC is set to the previous value.
Amendment 1 04/97
RAE/RAK–1N
Service Software
CONT
Page 7– 29