Nokia 9000i Service Manual page 175

Rae, rak-1 series
Hide thumbs Also See for 9000i:
Table of Contents

Advertisement

After Sales
Technical Documentation
input (Start value = Int)
output (Start value = Int)
loop (Start value = Off)
– External audio loop:
interface (Start value = HS)
– Logic controls
LCD Test Display (Start value = 1)
Load New Setup – generates the same kind of message as the save
function and asks for a setup file name. When the name is keyed in and
entered <Enter>, the file is loaded and all previously selections and
parameters are replaced with the values taken from the file. This has
same effect as command line parameter –f.
Both save file and load file functions have default names which are
generally the previously used name. For instance, if setup was saved to
file CONF.CON and the load file function is activated, the default value
becomes CONF.CON. Press the ENTER key to accept these files
parameters or press the BACKSPACE key to clear entry and key in
another filename and then press ENTER. The<Esc> key returns to the
previous menu. Invalid DOS filenames will give an error message.
If phone mode had Local value before setup file loading, the mode is
changed to Normal in the phone by special Normal mode message and all
functions caused by the change are done. If mode was Normal before
new setup, all needed setup file settings are sent to MS as in the previous
case, but phone mode change command is not sent to MS. Note next
exception: If phone mode is Normal and interface is M2BUS and
communication port is different in the setup file than the value before file
loading, then also Normal phone mode message has to be sent to MS.
Every time when phone mode change message from Local to Normal is
received by MS it makes reset to the whole MS.
2 – Initialize Phone
With this function you can initialize the phone to accept M2BUS
commands from the PC. This function should be used right after the
phone is connected to PC and powered up. This function also asks for the
PIN code if the phone's PIN asking is activated.
The initialization function performs the following subfunctions:
– MBUS registration
– Test mode message sent to the phone
– Phone mode set to GSM
– AFC value removed from info window
Amendment 1 04/97
RAE/RAK–1N
Service Software
Page 7– 17