5.2.2 Removing the Manual feed Pickup Roller

1) Remove the durm unit.
2) Remove the developing assembly (7.2.1
in Chapter5).
3) Remove the multifeeder tray.
4) Remove the 2 stepped screws [1] using
a screwdriver; then, keeping your hands
as shown, detach the pickup guide as-
sembly [2] by lifting it upward to the
front.
5) Remove the manual feed pickup roller
[3].
When Mounting
After mounting the manual feed
pickup roller, rotate the manual
feed pickup roller until it stops,
and check to make sure that the
cam [4] is as shown.