5.2.2 Removing the Manual feed Pickup Roller
1) Remove the durm unit.
2) Remove the developing assembly (7.2.1
in Chapter5).
3) Remove the multifeeder tray.
4) Remove the 2 stepped screws [1] using
a screwdriver; then, keeping your hands
as shown, detach the pickup guide as-
sembly [2] by lifting it upward to the
front.
5) Remove the manual feed pickup roller
[3].
When Mounting
After mounting the manual feed
pickup roller, rotate the manual
feed pickup roller until it stops,
and check to make sure that the
cam [4] is as shown.
COPYRIGHT© 2002 CANON INC.
2000
CANON iR1600/iR2000 REV.1 JAN. 2002
CHAPTER 6 PICKUP/FEDING SYSTEM
[1]
F06-502-03
[4]
[3]
F06-502-04
6-25