CHAPTER 3 IMAGE READING/PROCESSING SYSTEM

3.3 Detecting the Size of Originals

The machine uses combinations of states of original size sensors to detect the size of an
original with reference to the following table:
• Unchanged : The machine reads the output levels of the sensors at intervals of 0.125
sec after the copyboard cover open/closed sensor goes ON, and there is
no change in the output level (detecting an original).
• Changed
: The machine reads the output levels of the sensors at intervals of 0.125
sec after the copyboard cover open/closed sensor goes ON, and there is
change in the output level (not detecting an original).
A/B-Configuration
Original
size
A3
B4
A4R
A4
B5
B5R
None
3-6
Original size sensor
PS114
Unchanged Unchanged
Changed
Unchanged Unchanged Unchanged
Changed
Changed
Unchanged Unchanged
Changed
Unchanged
Changed
Changed
Changed
Changed
Inch-configuration
Original
size
PS115
11"X17"
Unchanged
LGL
Changed
LTR-R
Changed
LTR
Unchanged
None
Changed
A-configuration
Original size sensor
Original
size
PS115
A3
Unchanged
A4R
Changed
A4
Unchanged
None
Changed
T03-303-01
COPYRIGHT© 2002 CANON INC.
PS115
PS116
Unchanged Unchanged
Unchanged Unchanged
Changed
Changed
Unchanged
Changed
Original size sensor
PS116
Unchanged Unchanged
Unchanged
Unchanged
Unchanged
Changed
Changed
Changed
Changed
Changed
PS116
Unchanged
Unchanged
Changed
Changed
2000
PS117
Changed
Changed
Changed
Changed
PS117