Mechanical counter error: BK
This SC is only for NA models.
The machine detects the mechanical counter error when SP5987-001 is set
610
D
to "1".
Disconnected mechanical counter
Defective mechanical counter
Communication timeout error between IOB and finisher or mailbox
A break (low) signal is received from the finisher or the mailbox.
621
D
Disconnected cable
Defective IOB
Defective main board in the peripherals
Paper feed unit communication error
While the IOB communicates with a peripheral, an SC code is displayed if
one of following conditions occurs.
The IOB receives the break signal which is generated by the peripheral
622
D
only just after the main switch is turned on.
The IOB receives the break signal which is generated by URAT.
Defective main control board of the peripheral
Defective BCU or IOB
Disconnected peripheral
623
D
2nd Paper Bank communication error
This SC is not issued for this machine.
When a communication error signal between the 1st paper bank and 2nd
paper bank is received.