SP1-xxx: Feed-3
019 Wait Time: L: Thick 2
020 Wait Time: L: Thin
021 Wait Time: N: Plain
022 Wait Time: N: M-Thick
023 Wait Time: N: Thick 1
024 Wait Time: N: Thick 2
025 Wait Time: N: Thin
026 Temp.: Low: Plain
027 Temp.: Low: M Thick
028 Temp.: Low: Thick 1
029 Temp.: Low: Thick 2
030 Temp.: Low: Thin
031 Temp.: Norm: Plain
032 Temp.: Norm: M-Thick
033 Temp.: Norm: Thick 1
034 Temp.: Norm: Thick 2
035 Temp.: Norm: Thin
036 Low: Plain
037 Low: M-Thick
038 Low: Thick 1
039 Low: Thick 2
G179
CÓPIA NÃO CONTROLADA
down mode is activated or not after the time
specified with these SPs has passed.
Adjusts the threshold temperature of the fusing
unit to enter the CPM down mode.
[100 to 200 / 120 / 1 deg]
If the temperature of the fusing unit is less than
the temperature specified with these SPs, the
machine changes the CPM (adjustable with
SP1916-36 to -45).
Adjusts the CPM in the CPM down mode.
[20 to 45 / 45 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[20 to 45 / 45 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[5 to 25 / 25 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[5 to 15 / 15 / 5 cpm]
5-22