Ricoh G179 Service Manual page 240

G179 ricoh
Hide thumbs Also See for G179:
Table of Contents

Advertisement

SP2-xxx: Drum-1
5.6 SP2-XXX: DRUM-1
2001*
Charge Bias
Setting (Printing)
001
Adjusts the voltage applied to the charge roller for printing.
Setting (P Pattern)
002 Adjusts the voltage applied to the charge roller when making the VSDP ID
sensor pattern (for charge roller voltage correction). The actual charge roller
voltage is this value plus the value of SP2001-1.
2005*
Bias Control
Bias Correction 1
001 Adjusts the lower threshold value for the charge roller correction.
When the value of VSDP/VSG is greater than this value, the charge roller
voltage increases by 30 V (e.g., from –500 to –530).
Bias Correction 2
002 Adjusts the upper threshold value for the charge roller correction.
When the value of VSDP/VSG is greater than this value, the charge roller
voltage decreases by 30 V (absolute value).
Bias Adjustment 1
003
Adjusts the lower limit value for charge roller voltage correction.
Bias Adjustment 2
004
Adjusts the upper limit value for charge roller voltage correction.
Bias Adjustment 3
005
Adjusts the correction voltage adjustment step size.
G179
CÓPIA NÃO CONTROLADA
[1000 to 2000 / 1500 / 10 V]
[0 to 700 / 250 / 10 V]
5-24
CÓPIA NÃO CONTROLADA
[0.1 to 1 / 0.85 / 0.05 step]
[0.1 to 1 / 0.9 / 0.05 step]
[1000 to 2000 / 1500 / 10 vol]
[1000 to 2000 / 2000 / 10 vol]
[0 to 100 / 30 / 10 vol]
SM

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Aficio sp 8200dn

Table of Contents