Ricoh G179 Service Manual page 274

G179 ricoh
Hide thumbs Also See for G179:
Table of Contents

Advertisement

SP5-xxx: Mode-3
Sets the length of time (seconds) for the time-out when sent data is written to
the RCG during a call over the @Remote network.
[0 to 100 / 60 / 1 sec.]
RCG Read Timeout
010 Sets the length of time (seconds) for the timeout when sent data is written
from the RCG during a call over the @Remote network.
[0 to 100 / 60 / 1 sec.]
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port
80 on the @Remote network.
011
[0 to 1 / 0 / 1]
0: No. Access denied
1: Yes. Access granted.
013 RFU Timing
Function Flag
021 This SP displays the embedded RCG-N installation end flag.
1: Installation completed
2: Installation not completed
Install status
This SP displays the RCG device installation status.
022
0: RCG device not registered
1: RCG device registered
2: Device registered
Connect Mode (N/M)
023 This SP displays and selects the embedded RCG-N connection method.
0: Internet connection
1: Dial-up connection
Not time Expim (DFU)
061
Proximity of the expiration of the certification.
G179
CÓPIA NÃO CONTROLADA
5-58
CÓPIA NÃO CONTROLADA
SM

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Aficio sp 8200dn

Table of Contents