Ricoh G179 Service Manual page 239

G179 ricoh
Hide thumbs Also See for G179:
Table of Contents

Advertisement

040 Low: Thin
041 Plain
042 M-Thick
043 Thick 1
044 Thick 2
045 CPM: Normal: Thin
1930
OnOff Time Adjust
On Time Adjust
001
Adjusts the Off-On interval of the transfer belt contact motor. ("On" means
that the transfer belt is in contact with the drum.)
Off Time Adjust
002
Adjusts the On-Off interval of the transfer belt contact motor. ("Off" means
that the transfer belt is away from the drum.)
Tray Lock at Jam
1950
Not used
SM
CÓPIA NÃO CONTROLADA
Adjusts the CPM in the CPM down mode.
[30 to 45 / 45 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[5 to 25 / 25 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[5 to 15 / 15 / 5 cpm]
Adjusts the CPM in the CPM down mode.
[30 to 45 / 45 / 5 cpm]
[0 to 100 / 40 / 10 msec]
[0 to 100 / 20 / 10 msec]
[0 or 1 / 0 / 1 ] 0= OFF, 1= ON
5-23
CÓPIA NÃO CONTROLADA
SP1-xxx: Feed-3