Transfer Unit Belt Rotation Sensor
The Transfer Unit Belt Rotation Sensor is mounted inside the Housing Bias
Assembly.
1.
Remove the Housing Bias Assembly.
2.
Release 2 hooks that secure the sensor to the assembly.
3.
Disconnect the sensor (P/J330) from the harness.
Housing Bias
Assembly
Service Parts Disassembly
Transfer Unit Belt Rotation Sensor
s7400-474
8-91