OHP Sensor
1.
Open Door A.
2.
Remove the Sensor Cover from the back of Tray 1 (MPT).
3.
Disconnect the sensor from the harness (P/J450).
4.
Release the hooks that secures the sensor to Tray 1 (MPT).
Service Parts Disassembly
Tabs
OHP Sensor
Sensor Cover
s7400-458
s7400-459
8-31