94
Syntax
get sem
get set
get sfc
get sgi
get sgo
get slt
get spc
get ssb
get ssf
get ssg
get ssm
get sut
03-032-10158-04
PRELIMINARY
Parameters
Description
Returns the current exposure mode:
2 = Internal SYNC, internal PRIN, programmable line
rate and exposure time using commands ssf and set
3 = External SYNC, internal PRIN, maximum exposure
time
4 = Smart EXSYNC
5 = External SYNC and PRIN
6 = External SYNC, internal PRIN, programmable
exposure time
7 = Internal programmable SYNC, maximum exposure
time. Factory setting.
8 = Internal SYNC, internal PRIN, programmable
exposure time. Maximum line rate for exposure time.
Returns the current exposure time in µs.
Returns the FPN coefficient for the pixel number idicated.
x
x =pixel number within the range 1 to sensor pixel
count .
Returns the current input signal setting for the input
i
number specified where:
0 = disabled
1 = TTL
2 = LVDS
Returns the current output signal setting for the output
i
number specified where:
0 = disabled
1 = TTL
2 = LVDS
Returns the current lower threshold value.
Returns the PRNU coefficient for the specified pixel
x
number.
x =pixel number within the range 1 to sensor pixel
count .
Returns the current background subtract value.
t
t = Tap value. 0 for all taps or 1 to 2 for individual tap
selection depending on camera model.
Returns the current line/frame rate in Hz.
Returns the current digital gain setting.
t
t = tap selection, either 1 to 2 depending on camera
model, or 0 for all taps
Returns the current sensitivity mode where:
0 = Low sensitivity mode
1 = High sensitivity mode
2 = Tall pixel mode
Returns the current upper threshold value.
Spyder3 GigE User Manual