Spyder3 GigE User's Manual
Mnemonic
set GPIO input
set GPIO output
set lower threshold
set prnu coeff
set subtract background
set sync frequency
set system gain
set sensitivity mode
set upper threshold
DALSA
PRELIMINARY
Syntax
Parameters
sgi
i i
sgo
i i
slt
i
spc
x i
ssb
t i
ssf
i
ssg
t i
ssm
i
sut
i
Description
Sets the GPIO input signal.
i = input number in a range from 0 to 3
i = signal to use where:
0 = disabled
1 = TTL
2 = LVDS
Sets the GPIO output signal.
i = output number in a range from 0 to
3
i = output signal to use where:
0 = disabled
1 = TTL
2 = LVDS
The pixels below the lower threshold
are checked for and reported in the
end-of-line sequence in a range from 0 -
4095 .
Set the PRNU coefficient.
x =pixel number within the range 1 to
sensor pixel count .
i = PRNU value within the range 0 to
28671 .
Subtract the input value from the
output signal.
t = Tap value. 0 for all taps or 1 to
number of camera taps for individual tap
selection.
i = Subtracted value in a range from 0
to 4095 .
Set the frame rate to a value from
300 Hz to 37000 Hz (2k model) or
300 Hz to 68000 Hz (1k model). Value
rounded up/down as required.
Set the digital gain.
t = tap selection, either 1 to 2 , or 0 for
all taps
i = Digital gain in a range from 0 to
65535 . The digital video values are
multiplied by this number.
Sets the camera's sensitivity mode
where i is:
0 = Low sensitivity mode
1 = High sensitivity mode
2 = Tall pixel mode
The pixels equal to or greater than the
upper threshold are checked for and
reported in the end-of-line sequence in
a range from 0 - 4095 .
03-032-10158-04
101