Spyder3 GigE User's Manual
Mode 6: External Line Rate and Internally Programmable Exposure Time
Figure 21: EXSYNC controls Line Period with Internally controlled Exposure Time
EXSYNC
CR=Charge Reset
Mode 7: Internally Programmable Line Rate, Maximum Exposure Time
In this mode, the line rate is set internally with a maximum exposure time.
Figure 22: Mode 7 Camera Timing
Internal Sync set
with
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this mode, the exposure time is set internally with a maximum line rate.
Figure 23: Mode 8 Timing
CR=Charge Reset
DALSA
PRELIMINARY
Line Period
Readou
t
Programmable Period
Using
Command
set
Line Period
Exposure Time
Readout
Command
ssf
Readout
Frame Period
EXSYNC Falling
Edge ignored
during readout
Programmable Period
CR Exposure Time
Line Period
Readou
t
Programmable Period
Using
command
set
Line Period
Exposure Time
Readout
EXSYNC Falling
Edge ignored
during readout
Readout
CR Exposure Time
Frame Period
03-032-10158-04
59
Programmable Period