Diagnostics; Diagnostic Leds; Gate Status Led - Centsys D5-Evo Installation Manual

Light-industrial sliding gate operator
Hide thumbs Also See for D5-Evo:
Table of Contents

Advertisement

24. Diagnostics

Diagnostic LEDs

The D5-Evo controller has a series of diagnostic LEDs which indicate the state of the
inputs.
Normally-open inputs are indicated by a red LED, and normally-closed inputs by a green
LED. An illuminated red LED indicates that the signal is present (e.g. intercom button
pressed), while a non-illuminated green LED indicates that the signal is absent (e.g. IRB
broken).

Gate status LED

Off
On
Continuous slow flash
Continuous fast flash
One flash every two seconds
Two flashes every two seconds
Three flashes every two seconds
Safety close - green
On when the closing beam is not activated
Safety open - green
On when the opening beam is not activated
Lck/Stp - green
On when the Lck/Stp input is not activated
Trg - red
On when the trigger signal is present
Ped - red
On when the pedestrian signal is present
FRX - red
On when a free-exit signal is present
Aux - red
On when an auxiliary signal is present
Status- red
This LED indicated the status of the gate
as per the table below:
Gate is closed
Gate is partially or fully open
Gate is opening
Gate is closing
Pillar light override is activated
No mains present
Battery voltage is low
page 56