Ricoh M080 Service Manual page 159

Printers
Hide thumbs Also See for M080:
Table of Contents

Advertisement

Incorrect dial up connection
-001: Program parameter error
651
C
-002: Program execution error
Remote service: ID2 confict
652
C
Remote service: ID2 fraud
653
C
EEPROM Error
The EEPROM was not connected at
669
B
power on, or read/write operations
on the EEPROM failed.
Engine response error
670
D
Controller data transfer error
674
D
SM Appendix
An unexpected error occurs when
the modem (Cumin-M) tries to call
the center with a dial up connection.
Caused by a software bug
No action required because this SC
does not interfere with operation of
the machine.
EEPROM connected improperly
EEPROM missing
Engine board installed
incorrectly
Engine board defective
Controller board defective
2-11
Service Call Conditions