Night Set Mode - Daikin SUPER MULTI NX G Series Service Manual

Table of Contents

Advertisement

SiUS12-928_A
1.8

NIGHT SET Mode

Outline
When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail
The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in the
case of heating. This prevents excessive cooling in summer and excessive heating in winter to
ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Target temperature
Target temperature
Heating
Function and Control
 Duct-Free System
0.5˚C (0.9˚F)
0.5˚C (0.9˚F)
TIMER operation
NIGHT SET Mode ON
 Slim Duct Built-in System
1 hour
+0.5˚C (0.9˚F)
TIMER operation
temperature shift
NIGHT SET Mode ON
When the outdoor temperature is normal and the
room temperature is at the set temperature.
When the outdoor temperature is high (27˚C (81˚F) or higher).
Set temperature
Timer operation
Night Set Mode ON
(R11588)
0.5˚C (0.9˚F)
0.5˚C (0.9˚F)
Operation stops
30 minutes
at the set hours
+0.5˚C (0.9˚F) temperature shift
Target temperature remains the same
2˚C(3.6˚F)
Main Functions
(R12293)
(R10698)
36