Pressing and holding the CLEAR/MONITOR button
for 2.5 seconds toggles the user into and out of the
dynamic regroup groupset. A double beep will sound for
entry or exit. The display will indicate "REGRP_0x"
where "x" is a digit of 1 to 8 indicating the group when
dynamic regroup has been enabled by the user. If the
radio is in dynamic regroup and the user selects a group
that has not been regrouped, the display will show "NO
ENTRY". The radio will be prevented from transmitting
and receiving calls in this condition except for scanned
groups.

Emergency Operation

If the pre-programmed groupset on the currently se-
lected system contains an EMER/HOME group and the
radio is in dynamic regroup, the radio will declare the
emergency on the currently selected dynamic group
group.
Macro key operation permits the user to accomplish
a series of key strokes with a single "macro" key stroke.
Up to ten (10) macro keys can be defined, each capable
of executing up to twenty (20) key strokes, to any push-
button input (i.e., keypad keys, OPTION button, etc.).
Each macro key can be pre-programmed to activate
when pressed or when released.
A macro key may also be pre-programmed to change
the key stroke sequence the next time the macro key is
activated.