2-8-7. RET IN, TEST OUT Connector

(CN-2620 Board)

1. Remove the MIC panel assembly.
(Refer to Section 2-8-2.)
2. Remove the five screws, and remove the BNC assem-
bly.
3. Disconnect the harness from the connector (CN3) on
the CN-2620 board.
4. Unsolder the RET IN, TEST OUT connector from the
CN-2620 board.
5. Remove the nut to detach the RET IN, TEST OUT
connector.
CN-2620 board
Unsolder
Nut
Washer
CN3
BNC
assembly
TEST OUT connector
6. Install a new RET IN, TEST OUT connector by
reversing the steps above.
2-16
RET IN
connector
MIC panel assembly
Screws
(M2)
Screws
(M2)

2-8-8. SDI 1 Connector (HDC1500)

1. Remove the outside panel. (Refer to Section 1-4.)
2. Remove the two screws to detach the BNC bracket.
3. Disconnect the coaxial cable from the SDI 1 connec-
tor.
n
Be sure to hold the plug when disconnecting the
coaxial cable. Do not pull the cable.
4. Remove the nut to detach the SDI 1 connector.
Out side panel
Coaxial cable
Hold the plug to
OK
remove.
5. Install a new SDI 1 connector by reversing the steps
above.
n
Hold the plug of the coaxial cable, and connect it
perpendicularly to the connector.
Push the plug into the connector while turning it
clockwise and counterclockwise several times.
Connecting connector
Screws
(M2)
SDI 1
connector
BNC
bracket
Washer
Nut
Do not attempt to
NG
remove by pulling
the cable.
Hold the plug to connect
HDC1000/V1(E)