File System; File Structure - Sony HDC1000 Maintenance Manual

Hd color camera digital hdvs
Hide thumbs Also See for HDC1000:
Table of Contents

Advertisement

The HDC1000/1400/1500/1550/1580 are equipped with various file systems for managing data.
In this section, the menu operations are described as follows.
Example: When executing WRITE (CAM → MS) at the OPERATOR FILE page of the OPERATION
menu.
As for the details on the setup menu, refer to Section 5.

4-1. File Structure

The following six types of files are available. As for the items to be stored in each file, refer to Section 4-
8. " File Items".
1. Operator File
Stores the items displayed on the viewfinder and switch settings for camera operator. This file can be
stored in the memory stick, yet the video data (paint data) cannot be stored.
2. Preset Operator File
Stores the standard settings of Operator File.
This file can be stored in the camera, yet video data (paint data) cannot be stored.
3. Scene File
Stores the temporary video setting data according to the scene. This file can be stored in the camera
and memory stick.
4. Reference File
Stores the custom paint data adjusted by the video engineer. This file can be stored in the camera and
memory stick.
5. Lens File
Used for compensation of the deviation which generates by switching the lens extender from OFF to
ON and for compensation of the difference in the characteristics between lenses. This file is stored in
the camera.
6. OHB File
Used for adjustment of the CCD block maintenance. This file can be stored in the camera.
When STANDARD
is executed
Factory-set value 0
(*1): The additional data of each file is sent to each circuit on the unit.
HDC1000/V1(E)
Section 4

File System

Refer to Section 4-8. "File Items".
When lens extender setting is OFF, Flare R/G/B and
V Modulation Shading R/G/B/Master can be stored.
Auto Iris Gain can be stored.
When lens extender setting is ON, White R/B, Flare R/G/B and
V Modulation Shading R/G/B/Master can be stored.
Auto Iris Gain can be stored.
Refer to Section 4-8. "File Items".
R/G/B for each White Shading H SAW, H PARA, V SAW, VPARA can be stored.
R/G/B for each Black Shading H SAW, H PARA, V SAW, V PARA can be stored.
And OHB matrix and the ND offset can be stored.
Fig. 4-1. Structure of Paint Related Files
Scene File
Lens File
Reference File
OHB File
Output to
hardware
(*1)
4-1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdc1500Hdc1400Hdc1550Hdc1580

Table of Contents