2
CH RECALL SAFE field
Indicates the channels currently specified to Recall Safe function.
All parameters are affected by Recall Safe on these channels.
Some parameters are affected by Recall Safe on these channels.
Recall Safe has been canceled on these channels.
3
SET BY SEL button
Enables you to use the [SEL] keys on the panel to select channels that will be affected by
the Recall Safe function. Turn this button on, and then press the [SEL] key for the
channel to which you want to apply Recall Safe. Recall Safe will turn on. Press the same
[SEL] key once again to de-select the channel.
4
GLOBAL RECALL SAFE display field
Indicates the state of Recall Safe settings that are not made in units of channels, and the
Recall Safe settings for racks. Press this field to open the GLOBAL RECALL SAFE window.
These buttons correspond to the following parameters.
All input channel patching (including INSERT IN/OUT and DIRECT OUT
INPUT PATCH
patching)
INPUT NAME
All input channel names, icons, and channel colors
OUTPUT PATCH
All output channel patching (including INSERT IN/OUT patching)
OUTPUT NAME
All output channel names, icons, and channel colors
HA
All I/O devices, and HA-related parameters for external head amps
CH LINK
All channel link group settings
MUTE GROUP
Name of the mute group
NAME
CUSTOM FADER
Custom fader bank settings
BANK
GEQ RACK
Apply Recall Safe to GEQ racks 1–16, Effect racks 1–8, Premium racks 1–8
EFFECT RACK
individually.
PREMIUM RACK
FADER BANK
FADER BANK selections, GAIN/PAN/ASSIGN knob selection status (set in
SELECT
units of blocks)
PORT TO PORT HA PORT TO PORT settings
PORT TO PORT
PORT TO PORT patching
PATCH
NOTE
If a dual-type GEQ rack or Premium rack has been selected, you can apply Recall Safe to rack
A and B individually. For other racks, the setting for racks A and B will be linked.
5
Channel select button
Selects the channel for which you want to set the Recall Safe function.
NOTE
Switching channels using this button will not affect the channel selection on the top panel.
6
Selected channel display
This area indicates the icon, number, color, and name of the currently-selected channel.
7
APPLY TO ALL INPUT button (input channels only)
Turn on this button to apply the Recall Safe parameter selection for one input channel
to all other input channels.
Turn this on if you want to apply Recall Safe to the same parameters for all input
channels.
8
APPLY TO ALL OUTPUT button (shown only for output channels)
Turn on this button to apply Recall Safe parameter selection for one output channel to
all other output channels.
Turn this on if you want to apply Recall Safe to the same parameters for all output
channels.
9
SAFE PARAMETER SELECT field (excluding DCA groups)
Selects Recall Safe parameters for the selected channel.
The button indication varies depending on the channel type.
• Input channel
NOTE
ST IN channels do not feature INSERT, INSERT PATCH, and DIRECT OUT button.
• MIX channel
• MATRIX channel
• STEREO channel