Parameter Change - Yamaha QL5 Reference Manual

Digital mixing console
Hide thumbs Also See for QL5:
Table of Contents

Advertisement

[Conversion from actual data to bulk data]
d[0-6]: actual data
b[0-7]: bulk data
b[0] = 0;
for( I=0; I<7; I++){
if( d[I]&0x80){
b[0] |= 1<<(6-I);
}
b[I+1] = d[I]&0x7F;
}
[Recovery from bulk data to actual data]
d[0-6]: actual data
b[0-7]: bulk data
for( I=0; I<7; I++){
b[0] <<= 1;
d[I] = b[I+1]+(0x80&b[0]);
}

3.3 PARAMETER CHANGE

Reception
This message is echoed if [PARAMETER CHANGE ECHO] is ON.
This message is received if [PARAMETER CHANGE Rx] is ON and [Rx CH] matches
the Device number included in the SUB STATUS. When a PARAMETER CHANGE is
received, the specified parameter will be controlled. When a PARAMETER
REQUEST is received, the current value of the specified parameter will be
transmitted as a PARAMETER CHANGE with its Device Number as the [Rx CH].
Transmission
If [PARAMETER CHANGE Tx] is ON, and you edit a parameter for which
CONTROL CHANGE transmission has not been enabled, a PARAMETER CHANGE
will be transmitted with the [Tx CH] as its device number.
In response to a PARAMETER REQUEST, a PARAMETER CHANGE will be
transmitted with [Rx CH] as its device number.
Command
rx/tx
QL series native parameter change
F0 43 1n 3E 19 ... F7
rx/tx
RARAMETER CHANGE
QL series native parameter request
F0 43 3n 3E 19 ... F7
rx/tx
PARAMETER REQUEST
4 PARAMETER CHANGE details
4.1 CURRENT SCENE, SETUP, BACKUP, USER SETUP
4.1.1 Format (PARAMETER CHANGE)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
The corresponding parameter will be changed immediately the data is received.
Transmission
Data will be transmitted with the [Device Number] in [Tx CH] when [PARAMETER
CHANGE Tx] is on and the parameter is not registered on the [CONTROL
CHANGE EVENT LIST].
STATUS
ID No.
SUB STATUS
GROUP ID
MODEL ID
DATA Category 0ccccccc cc
DATA
EOX
Function
4.1.2 Format (PARAMETER REQUEST)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
The corresponding parameter will be changed via PARAMETER CHANGE
immediately the data is received.
STATUS
ID No.
SUB STATUS
GROUP ID
MODEL ID
DATA Category 0ccccccc cc
DATA
EOX
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
0001nnnn 1n
00111110 3E
Digital mixer
QL Series
00010010 19
Element no High.
0eeeeeee eh
Element no Low.
0eeeeeee el
Index no High.
0iiiiiii ih
Index no Low.
0iiiiiii il
Channel no High.
0ccccccc ch
Channel no Low.
0ccccccc cl
Data
0ddddddd dd
:
:
End of exclusive
11110111 F7
System exclusive message
11110000 F0
Manufacture's ID number (YAMAHA)
01000011 43
n=0-15 (Device number=MIDI Channel)
0001nnnn 3n
Digital mixer
00111110 3E
QL Series
00010010 19
Element no High.
0eeeeeee eh
Element no Low.
0eeeeeee el
Index no High.
0iiiiiii ih
Index no Low.
0iiiiiii il
Channel no High.
0ccccccc ch
Channel no Low.
0ccccccc cl
End of exclusive
11110111 F7
35
4.1.3 Data category
Data Category
Current Scene /Setup/Backup/
0x01
00000001
User Setup Data
4.2 FUNCTION CALL – LIBRARY STORE, RECALL –
4.2.1 Format (PARAMETER CHANGE)
Reception
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS match.
The data will be echoed when [PARAMETER CHANGE ECHO] is on.
The corresponding parameter will be changed immediately the data is received.
Transmission
Data will be transmitted with the [Device Number] (MIDI CH) in [Tx CH] when
[PARAMETER CHANGE Tx] is on.
STATUS
11110000 F0
System exclusive message
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS
0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
MODEL ID
00010010 19
QL Series
OTHER DATA
DATA CATEGORY 00000000 00
(ASCII CODE)
FUNCTION NAME 01001100 "L"
(ASCII CODE)
01101001 "i"
01100010 "b"
(ASCII CODE)
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
0fffffff ff
(ASCII CODE)
(ASCII CODE)
0fffffff ff
(ASCII CODE)
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
0mmmmmmm mm
(ASCII CODE)
(ASCII CODE)
0mmmmmmm mm
Number High
DATA
0nnnnnnn nh
Number Low
0nnnnnnn nl
0ccccccc ch
Channel High
Channel Low
0ccccccc cl
End of exclusive
EOX
11110111 F7
4.2.2 Function Name
Function Name
Store
"LibStr__"
Recall
"LibRcl__"
Unknown Factor Store
"LibUnStr"
Unknown Factor Recall
"LibUnRcl"
Store Undo (only Score)
"LibStrUd"
Recall Undo (only Scene)
"LibRclUd"
Name
Data List

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ql1

Table of Contents