 BUS SETUP field
This field enables you to make bus-related settings.
D
BUS SETUP button
Press this button to open the BUS SETUP window, in which you can make MIX bus/
MATRIX bus-related settings.
 DATE/TIME button
Press this button to open the DATE/TIME window, in which you can set the date and time.
 NETWORK button
Press this button to open the NETWORK window, in which you can set the network address.
 Indicator field
This field displays various information about the console.
E
BATTERY indicator
Indicates the status of the internal battery.
NOTE
The LOW or NO indication will appear if the battery runs down. In this case, immediately contact
your Yamaha dealer or a Yamaha service center listed at the end of the operating manual
(separate document) to have the backup battery replaced.
F
POWER SUPPLY indicator
Indicates the currently-running power supply.
• INT .........................Internal
G
Version indicator
Indicates the version number of the CPU and DANTE module.
 CONSOLE LOCK button
This button executes the Console Lock function. If the console password has been set,
pressing this button will open the AUTHORIZATION window. Enter the correct password to
execute Console Lock.
If the console password has not been set, pressing this button will execute Console Lock
immediately.
 CONTRAST/BRIGHTNESS field
This field enables you to set the LCD brightness and contrast.
H
BANK A/BANK B buttons
Select a bank to which you want to save the brightness and contrast settings. You can
save two different settings in bank A and B, and switch between them if desired.
I
CONTRAST NAME knob
Adjusts the contrast of the channel name display.
J
BRIGHTNESS NAME knob
Adjusts the brightness of the channel name display.
BRIGHTNESS CH COLOR knob
Adjusts the brightness balance of the channel color and the channel name display.
BRIGHTNESS SCREEN knob
Adjusts the brightness of the display.
BRIGHTNESS PANEL knob
Adjusts the brightness of the panel LEDs.
BRIGHTNESS LAMP knob
Adjusts the brightness of the lamp connected to the LAMP connector.

User settings

User Level settings allow you to restrict the parameters that can be operated by each user, or
to change the settings of USER DEFINED keys and preference settings for each user.
Settings for each user can be stored as a "user authentication key" inside the console or
together on a USB flash drive, allowing users to be switched easily. This can be convenient in
the following situations.
• Unintended or mistaken operation can be prevented.
• The range of functionality operable by an outside engineer (guest engineer) can be
limited.
• In situations in which multiple operators alternate with each other, output settings etc.
can be locked to prevent unintended operations.
• Preferences of each operator can easily be switched.
User types and user authentication keys
There are three types of user, as follows. To operate the QL series console, you must log-in
as a user.
• Administrator.......... The administrator of the QL console can use all of its
functionality. Only one set of Administrator settings is internally
maintained in the console. The Administrator can create user
authentication keys for other users. Even if the console was
locked by another user, the administrator can use the
administrator password to unlock it.
160