Acceleration/Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45) - Mitsubishi Electric FR-E500 Instruction Manual

Fr-e500 series transistorized inverter
Hide thumbs Also See for FR-E500:
Table of Contents

Advertisement

Note: 1. The multi-speed settings override the main speeds (across terminals 2-5, 4-5).
2. The multi-speeds can also be set in the PU or external operation mode.
3. For 3-speed setting, if two or three speeds are simultaneously selected,
priority is given to the frequency setting of the lower signal.
4. Pr. 24 to Pr. 27 and Pr. 232 to Pr. 239 settings have no priority between
them.
5. The parameter values can be changed during operation.
6. When terminal assignment is changed using Pr. 180 to Pr. 183, the other
functions may be affected. Check the functions of the corresponding
terminals before making setting.
4.2.5 Acceleration/deceleration time
(Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45)
Pr. 7 "acceleration time"
Pr. 8 "deceleration time"
Pr. 20 "acceleration/deceleration reference frequency"
Pr. 21 "acceleration/deceleration time increments"
Pr. 44 "second acceleration/deceleration time"
Pr. 45 "second deceleration time"
Used to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster
speed increase/decrease.
Parameter
Factory Setting
Number
0.1K to 3.7K
7
5.5K, 7.5K
0.1K to 3.7K
8
5.5K, 7.5K
20
21
0.1K to 3.7K
44
5.5K, 7.5K
45
Setting Range
5s
0 to 3600s/0 to 360s
10s
5s
0 to 3600s/0 to 360s
10s
60Hz
1 to 400Hz
0
5s
0 to 3600s/0 to 360s
10s
0 to 3600s/
9999
0 to 360s, 9999
Related parameters
Pr. 3 "base frequency"
Pr. 29 "acceleration/deceleration
pattern"
0: 0 to 3600s
0, 1
1: 0 to 360s
9999: acceleration time =
77
PARAMETERS
Remarks
deceleration time
4