4.2.4 Multi-speed operation
(Pr. 4, Pr. 5, Pr. 6, Pr. 24 to Pr. 27, Pr. 232 to Pr. 239)
Pr. 4 "3-speed setting (high speed)"
Pr. 5 "3-speed setting (middle speed)"
Pr. 6 "3-speed setting (low speed)"
Pr. 24 to Pr. 27 "multi-speed setting
Pr. 232 to Pr. 239 "multi-speed setting
Used to switch between the predetermined running
speeds.
z Any speed can be selected by merely switching
on/off the corresponding contact signals (RH, RM, RL, REX signals).
z By using these functions with Pr. 1 "maximum
frequency" and Pr. 2 "minimum frequency", up to 17 speeds can be set.
z Valid in the external operation mode or combined mode (Pr. 79 = 4).
When Pr. 79 = 4, the contact signals (RH, RM, RL, REX signals) are made valid.
Parameter Number
4
5
6
24 to 27
232 to 239
Speed 1
(high speed)
Speed 2
(middle speed)
Speed 3
(low speed)
ON
RH
ON
RM
ON
RL
<Setting>
y Set the running frequencies in the corresponding parameters.
y Each speed (frequency) can be set as desired between 0 and 400H z during inverter operation.
After the required multi-speed setting parameter has been read, the setting can be
changed by pressing the
key, press the
the set frequency.
y Use any of Pr. 180 to Pr. 183 to assign the terminal used to input the REX signal.
(speeds 4 to 7)"
(speeds 8 to 15)"
Factory Setting
60Hz
30Hz
10Hz
9999
9999
Speed 5
Speed 6
Speed 4
Speed 7
Time
ON
ON
ON
ON
ON
ON
ON
ON
/
key (
key when using the parameter unit (FR-PU04)) to store
SET
WRITE
Pr. 1 "maximum frequency"
Pr. 2 "minimum frequency"
Pr. 29 "acceleration/deceleration
Pr. 79 "operation mode
Pr. 180 to Pr. 183 (input terminal
Setting Range
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz, 9999
0 to 400Hz, 9999
Speed 10
Speed 9
Speed 8
RH
ON ON
RM
ON
RL
ON ON ON ON ON ON
REX
key. In this case, when you release the
76
PARAMETERS
Related parameters
pattern"
selection"
function selection)
Remarks
9999: Not selected
9999: Not selected
Speed 11
Speed 12
Speed 13
Speed 14
Speed 15
Time
ON ON ON ON
ON ON
ON
ON
ON
ON
ON
/

Hide quick links: