Mitsubishi Electric FR-E500 Instruction Manual page 93

Fr-e500 series transistorized inverter
Hide thumbs Also See for FR-E500:
Table of Contents

Advertisement

<Setting>
y Use Pr. 21 to set the acceleration/deceleration time and minimum setting
increments:
Set value "0" (factory setting) ....0 to 3600 seconds (m inim um setting increm ents: 0.1 second)
Set value "1"..............................0 to 360 seconds (m inim um setting increm ents: 0.01 second)
y Use Pr. 7 and Pr. 44 to set the acceleration time required to reach the frequency set
in Pr. 20 from 0Hz.
y Use Pr. 8 and Pr. 45 to set the deceleration time required to reach 0Hz from the
frequency set in Pr. 20.
y Pr. 44 and Pr. 45 are valid when the RT signal is on.
y Set "9999" in Pr. 45 to make the deceleration time equal to the acceleration time
(Pr. 44).
Note: 1. In S-shaped acceleration/deceleration pattern A (refer to page 86), the set
time is the period required to reach the base frequency set in Pr. 3.
• Acceleration/deceleration time calculation expression when the set
frequency is the base frequency or higher
4
9 ×
t =
• Guideline for acceleration/deceleration time at the base frequency of 60Hz
(0Hz to set frequency)
Acceleration/
deceleration tim e (sec.)
2. If the Pr. 20 setting is changed, the settings of calibration functions Pr. 903
and Pr. 905 (frequency setting signal gains) remain unchanged.
To adjust the gains, adjust calibration functions Pr. 903 and Pr. 905.
3. When the setting of Pr. 7, Pr. 8, Pr. 44 or Pr. 45 is "0", the acceleration/
deceleration time is 0.04 seconds. At this time, set 120Hz or less in Pr. 20.
4. When the RT signal is on, the other second functions such as second torque
boost are also selected.
5. If the shortest acceleration/deceleration time is set, the actual motor
acceleration/deceleration time cannot be made shorter than the shortest
acceleration/deceleration time determined by the mechanical system's
2
GD
and motor torque.
Pr.20
Pr.7
Pr.44
Acceleration
T
5
× f
2
+
9 T
2
(Pr. 3)
T: Acceleration/deceleration time setting (sec.)
f : Set frequency (Hz)
Frequency setting (Hz)
5
15
Running frequency
Time
Pr.8
Pr.45
Deceleration
60
120
5
12
15
35
78
PARAMETERS
200
400
27
102
82
305

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e520Fr-e540Fr-e510w

Table of Contents