Mitsubishi Electric FR-E500 Instruction Manual page 197

Fr-e500 series transistorized inverter
Hide thumbs Also See for FR-E500:
Table of Contents

Advertisement

(For the FR-E540-1.5K to 7.5K-NA)
1) Remove the front cover
(Refer to page 5.).
2) Unplug the fan connector.
The cooling fan is connected to
the cooling fan connector beside
the main circuit terminal block of
the inverter. Unplug the
connector.
3) Remove the inverter and cooling
fan.
Push in the direction of arrow A
and pull out in the direction of
arrow B.
4) Remove the cooling fan and
cooing fan cover.
The cooling fan is secured by the
fixing catches.
You can remove the cooling fan
and cooling fan cover by
disengaging the fixing catches.
PROTECTIVE FUNCTIONS
A
A
181
Fan connector
B
Cooling fan
Cooling fan cover