5.3.8 Measurement of main circuit voltages, currents and powers

z Measurement of voltages and currents
Since the voltages and currents on the inverter power supply and output sides include
harmonics, accurate measurement depends on the instruments used and circuits
measured.
When instruments for commercial frequency are used for measurement, measure the
following circuits using the instruments given on the next page.
Three-phase 200V
power input
Three-phase 400V
power input
Single-phase 100V
power input
3-phase
power
Instrument types
Note: 1. Use FFT (Fast Fourier Transforms) to measure the output voltage
accurately.
It cannot be measured accurately with a meter or general instrument.
2. For FR-E510W-0.1K to 0.75K-NA do not use At, Vt, Vs and W13.
Input
voltage
Input
current
Inverter
Ar
R (L
W11
Vr
As
S (L
W12
Vs
At
T (L
W13
Vt
P (+)
2
+
Typical Measuring Points and Instruments
PROTECTIVE FUNCTIONS
U
Au
)
W12
1
Vu
V
Av
)
2
Vv
Aw
W
)
W22
3
Vw
N (-)
5
V
(Note 2)
185
Output
voltage
Output
current
To motor