logged, reported to programmed telephone number and displayed on the LCD to warn the user.
Detection Off is set as factory default.
e) Final Door
If set to On, when the system is being Away Armed and a Door Contact set to Entry attribute is
closed before the Exit Delay timer expires, the system will enter Away Arm mode immediately even
if the Exit Delay timer has not expired yet. If set to Off, the system will only enter Away Arm mode
after the Exit Delay Timer has expired.
Final Door Off is set as factory default.
f) Siren Tamper
This function is only used for optional external sirens. If the Control Panel has included external
siren in the system, their tamper switches can be enabled and disabled remotely.
Siren Tamper On is set as factory default.
When the Siren Tamper is turned off, it will automatically revert to On after about an hour if not
switched back.
NOTE: For other devices, the tamper function will be disabled when the Control Panel is under
Programming Mode.
g) H. Temperature (Optional Temperature Sensor Required)
The Control Panel features High and Low Temperature report function which requires a
Temperature Sensor to use.
The H. Temperature option is for you to set the High Temperature Threshold. When the
temperature exceeds this threshold by 1°C, a SMS report will be sent to programmed telephone
number.
You can set the temperature within the range of -10°C to +50°C
When entering temperature value, press Up key to select negative value. Down key to select
positive value.
When the temperature drops to 3°C below the threshold, a SMS report will be sent to
programmed telephone number to notify the recipient of High Temperature Restoration.
You can set a High Temperature Threshold and choose to enable or disable the reporting
function. If reporting is disabled, the system will not send out report when the temperature
exceeds the threshold, but a log event will still be recorded in system
High Temperature Warning is Disabled by factory default
h) L. Temperature (Optional Temperature Sensor Required)
The system will send Low Temperature SMS reports when temperature drops to 1°C below the
Low Temperature Threshold.
When the temperature returns to 3°C above the threshold, a SMS report will be sent to
programmed telephone number to notify the recipient of Low Temperature Restoration.
Low Temperature setting format is the same as High Temperature setting.
Low Temperature Threshold must be at least 4°C lower than High Temperature Threshold.
Low Temperature Warning is Disabled by factory default.