4. Select the report type for this telephone number, there are 2 choices:
Voice Report – The Control Panel will dial the telephone number and play pre-recorded voice
message according to the event upon answer.
Telephone number set to Voice Report will be marked with "V" in the telephone number menu.
SMS Report – The Control Panel will send a SMS message to the telephone number to notify
the user. For SMS report, you also need to select the event type to be reported with this
telephone number:
All Event – All events will be reported
Telephone number set to All Events will be marked with "X" in the tel. number menu.
Alarm Event – Only alarm event will be reported
Telephone number set to Alarm Events will be marked with "A" in the tel. number menu.
Status Event – Only system status event will be reported.
Telephone number set to Status Events will be marked with "S" in the tel. number menu.
Record Msg.
Use the function to record your address message for Voice Report, the maximum length of the
message is 10 seconds.
1. If no message was previously recorded, the display will show "Start Recording After the Beep"
If you have already recorded a message, the display will ask you to confirm if you want to
change the message, press "OK" to confirm.
2. After 2 seconds, the Control Panel will sound one beep, you can now start to record the
message.
3. Speak clearly and slowly for the Control Panel to record your address. When you finish
recording, press "OK" to stop recording, the recording will automatically stop when it reaches
10 second
NOTE: If you do not record your own Address Message, the system will play default alarm
message when reporting. The default message is "Alarm System."
Test Report
This function allows you to test whether telephone function is working properly or not with the pre-
set telephone numbers.
1. Your telephone numbers will be displayed, select the desired number and press "OK".
2. The Control Panel will dial the telephone number:
3. For Voice Report telephone numbers, upon successful connection, the Panel will play pre-
recorded voice messages one by one for 85 seconds before hanging up. The messages include:
Address Message/Emergency Message/Fire Message/Burglar Message/Medical Message.
The call recipient can end the call by pressing DTMF "#9" or hanging up the telephone. If the
call recipient does not end the call, the Panel will hang up the telephone automatically after 85
seconds.
4. For SMS Report telephone number, a SMS test report message will be sent.