<Cleaning of the Pre-Image Transfer Guide Plate>
(3)
Application of Toner
NOTE
• Perform these steps when the PC Drum and/or Cleaning Blade have been replaced.
18. Pour one packet of developer.
NOTE
• Shake the packet of developer well before pouring.
• When the developer has been replaced, run
"ATDC Sensor Automatic Adjustment."
D-61
19. Using a soft cloth dampened with alcohol, wipe
the Pre-Image Transfer Guide Plate clean of dirt.
1. With the Cleaning Assy separated from the
Developing Assy, install the PC Positioning Jig in
the rear of the Developing Assy.
NOTE
• Ready the PC Positioning Jig (Pivot Shaft) sepa-
rately. (It can be ordered. For details, see the
Parts Manual.)
4022D034AA
2. Using a brush, apply a light coat of toner to the
surface of the PC Drum.
4021U008AB
D-34