Code No.
Adjust the zoom ratio in the FD direction on the ADF side.
It is used when the machine is set up, the PH Unit or Scanner Drive
Cables have been replaced, or the Scanner has been removed.
--7
Description (%) 9.48............................100 ..................... 105.2
Adjust registration in the CD direction on the ADF side.
It is used when the machine is set up, or the PH Unit or CCD Unit has
been replaced.
--8
Setting
Description (mm) -8.0 .............................. 0 ......................... +8.0
Adjust registration in the FD direction on the ADF side.
It is used when the PH Unit or Scanner Drive Cables have been
replaced, or the Scanner has been removed.
--9
Setting
Description (mm) -5 ................................. 0 ............................ +5
Adjust the ATDC Sensor voltage.
It is used when an IU of another machine is to be used or the T/C con-
trol voltage is to be changed.
-10
Description (V) 5.39........................... 6.79....................... 8.15
The value, to which F-8 (ATDC Sensor Automatic Adjustment) has
been adjusted, is to be the setting value.
Be sure to set to "1" whenever Memory Clear has been effected on
the 18-cpm machine.
-11
Setting
This function is used to produce a test print, when a check is made
after a setting value of an Adjust function has been changed and on
-12
image.
<Procedure>
1. Select the paper source (Bypass Tray cannot be selected).
2. Press the Start key to let the machine produce a test print.
-20
This test is for factory adjustment only and should NOT be used.
Setting (The default is
<ADF FD Zoom adjustment>
Setting
87..............................
<ADF CD Registration adjustment>
20 ..............................
<ADF FD Registration adjustment>
50 ..............................
<ATDC Sensor Gain Manual adjustment>
Setting
123............................
0
<Test Print>
S-29
Highlighted
).
........................ 113
100
........................ 180
100
........................ 150
100
........................ 186
155
1