Black streaks or bands

Section Step
Output
1
PC Drum is dirty or scratchy.
system
2
Foreign matter (such as paper dust)
sticks to the Cleaning Blade of IU or the
blade curves upward.
3
DB of IU is plugged with foreign matter
(such as paper dust).
4
PC Drum Charge Corona grid mesh and
Comb Electrode are dirty, scratchy,
deformed, damaged, or out of position.
5
Left Fusing Roller is dirty or scratchy.
6
PH window of the PH Unit is dirty or
scratchy.
Input
1
Original Glass is dirty, scratchy, worn, or
system
damaged.
2
Shading sheet reading portion (the por-
tion on the backside of the Original
Glass to which Original Width Scale is
affixed) is dirty.
3
Scanner mirrors are dirty, scratchy, or
damaged.
4
Exposure Lamp (LA2) is dirty.
5
CCD Unit lens and CCD surface are
dirty or scratchy.
<Check Procedure>
Remove lens cover to check for possible
contamination.
6
CCD Board (copier: PWB-J) connector
is loose.
7
Control Board (copier: PWB-C) connec-
tor PJ1A is loose.
Check
T-51
Result
Action
YES • Clean or change.
YES • Remove foreign mat-
ter, correct, or change.
YES • Remove foreign matter.
YES • Clean or change.
YES • Clean or change.
YES • Clean or change.
NO
• Change IU.
YES • Clean or change.
YES • Clean.
YES • Clean or change.
YES • Clean or change.
YES • Clean or change.
YES • Reconnect.
YES • Reconnect.
NO
• Change CCD Unit.
• Change Control Board
(copier: PWB-C).