Blank Streaks Or Bands - Minolta Di152 Service Manual

Hide thumbs Also See for Di152:
Table of Contents

Advertisement

(7)

Blank streaks or bands

Section Step
Output
1
PC Drum ground terminal is dirty,
system
scratchy, deformed, or damaged.
2
DB of IU is plugged with foreign matter
(such as paper dust).
3
PC Drum Charge Corona grid mesh and
Comb Electrode are dirty, scratchy,
deformed, or damaged.
4
Post-fusing guide plate is dirty, scratchy,
deformed, worn, or damaged.
5
PH window of the PH Unit is dirty,
scratchy, or damaged.
Input
1
Original Glass is dirty, scratchy, worn, or
system
damaged.
2
Shading sheet reading portion (the por-
tion on the backside of the Original
Glass to which Original Width Scale is
affixed) is dirty.
3
Scanner mirrors are dirty, scratchy, or
damaged.
4
CCD Unit lens and CCD surface are
dirty or scratchy.
<Check Procedure>
Remove lens cover to check for possible
contamination.
5
CCD Board (copier: PWB-J) connector
is loose.
6
Control Board (copier: PWB-C) connec-
tor PJ1A is loose.
Check
T-53
Result
Action
YES • Clean, correct, or
change.
YES • Remove foreign matter.
YES • Clean, correct, or
change.
YES • Clean or change.
YES • Clean or change.
NO
• Change IU.
YES • Clean or change.
YES • Clean.
YES • Clean or change.
YES • Clean or change.
YES • Reconnect.
YES • Reconnect.
NO
• Change CCD Unit.
• Change Control Board
(copier: PWB-C).