(11) Memory Clear; (12) Total Clear; (13) Adf Document Passage Test - Minolta Di152 Service Manual

Hide thumbs Also See for Di152:
Table of Contents

Advertisement

(11) Memory Clear

• This function is used to clear all data except that of the various electronic counters.
<Procedure>
1. Press the Start key to display "CLr" on the Display.
2. Press the Start key to blank out the Display.
Then, "CLr" will reappear.
3. Turn OFF and ON the Power Switch.

(12) Total Clear

• This function is used to clear all data of the various electronic counters.
<Procedure>
1. Press the Start key to display "tCL" on the Display.
2. Press the Start key to blank out the Display.
Then, "tCL" will reappear.
3. Turn OFF and ON the Power Switch.
Data Cleared
Jam display
Trouble display
Erratic operation/display
Utility (*1)
Tech.Rep.Mode (*2)
Security
Adjust
Job programs
Electronic counters
: Cleared —: Not cleared
*1: Except Copy Track, Input Account, and Total Counter Display by Account.
*2: Except Marketing Area Setting and Serial No. Display.

(13) ADF Document Passage Test

• This function is used to check for correct document passage through the ADF when a
document misfeed occurs.
<Procedure>
1. Load a paper stack in the Document Feeding Tray.
2. Press the Start key to let the ADF start feeding the paper.
3. Press the Stop key to stop the sequence.
For details, see the relevant option service manual.