Service Menu

Submenu Aux2 Configuration

Select the AUX2 CONFIG MENU from the SYSTEMS MENU with the UP and DOWN keys and open the menu
step with the PLUS (V+) key.
The AUX2 CONFIG MENU shows following operational steps:
Setup
No signal
Temperatures 2
Aux1 I/O
Aux2 I/O
Aux3 I/O
Backlight
Close and save this menu step by pushing the MENU key once.
© 02.07 TAMUZ - LCD Video Monitors
Aux2 Configuration
No Function
2
Over/Under temp.
On above temp.
2
On below temp.
2
2
Temperature
2
Note: This menu is normally hidden and for service purposes only. Don't use to modify for
your individual use.
disables the AUX2 I/O feature
enables the AUX2 I/O feature to trigger the AUX2 as
an alarm when the current measured temperature is
over or under the set threshold value. This can be
used for switching external devices
enables the AUX2 I/O feature to trigger the AUX2 as
an alarm when the current measured temperature is
above the set threshold value. This can be used for
switching external devices
enables the AUX2 I/O feature to trigger the AUX2 as
an alarm when the current measured temperature is
below the set threshold value. This can be used for
switching external devices
60 °C
select the threshold for the temperature to trigger the
AUX1 as an alarm to be used for switching external
HCM Series Broadcast Monitor
GOLDEN EAGLE
Help
devices
Page - 88 -