Service Interface; Probe Interface - TAMUZ HCM 112 Operation Manual

Golden eagle series
Table of Contents

Advertisement

Connections of the Monitor

Service Interface

For some special application a so-called service interface is helpful to control or maintain the monitor
firmware by external devices, like a PC system.
This service interface is built-in the GPI/O port. The pin-out is shown in following table:
Pin
This port is available for the GOLDEN EAGLE HCM 1xx series monitor (factory built-in at order).
This service interface can be used by service technicians to update the firmware. A special adapter
cable is necessary to connect to a PC RS232.

Probe Interface

All TAMUZ GOLDEN EAGLE series models have a probe port built-in at the front for alignment appli-
cations. This port communicates with a color probe, like the TAMUZ AAC probe PM5639-T.
This port is standard at the GOLDEN EAGLE HCM 1xx series monitors.
This service interface can be used by service technicians to align the monitor in colormetry and bright-
ness.
© 02.07 TAMUZ - LCD Video Monitors
Function
1
GPI Tally Green, closed contact +
2
GPI Tally Red, closed contact +
3
GPI 16:9 / 4:3, closed contact +
4
GPI Input SDI 1, closed contact +
5
GPI Input SDI 2, closed contact +
6
GPI Input SDI 3, closed contact +
7
GPO Input SDI 1 active, +5 V
8
GPO Input SDI 2 active, +5 V
Note: Do not connect other equipment then the recommended RS232 adapter to this port.
The monitor and the connected device may become destroyed.
Note: Do not connect other equipment then the recommended color analyzer probe to this
port. The monitor and the connected device may become destroyed.
Pin
Function
9
GPO Input SDI 1 active, +5 V
10
Ground (GND)
11
Not Connected
12
Not Connected
13
RS 232 +
14
RS 232 -
15
Ground