Service Section
Service Section
Changing a faulty Fuse
The electronics of the GOLDEN EAGLE HCM 1xx series monitor is protected by an integrated fuse.
The fuse is placed on the interface board. In case of an electronic defect or any other reason of dra-
wing a high current, the fuse will release. To exchange the fuse, you need to open the monitor and re-
place the broken fuse with a spare (2 A MT type 20 x 5 mm).
1. Step: Open the Monitor
To exchange the broken fuse, you have to open the GOLDEN EAGLE HCM 1xx series monitor.
Use a 2,5 mm allen-key screw driver to turn out the eight screws at the monitor front cover.
After turning off the eight screws, open carefully the monitor housing.
The front panel contains the LCD screen and the interface board. Flip the unit down.
2. Step: Exchange the Fuse
The internal fuse is placed on the interface board (highlighted in the picture below).
Take the broken fuse out of his setting and replace with a spare. (2 A MT type 20 x 5 mm)
3. Step: Reassemble the Monitor
Finally you can reassemble the monitor as described in step 1.
© 02.07 TAMUZ - LCD Video Monitors
Note: Be careful during turning off the screws at the monitor front. Us the correct screw driver
to open the screws.
Note: Do not use a different fuse type as described, the monitor can otherwise be destroyed.