Type
Power
Video
Unshielded
Twisted Pair
(UTP) Video
Data
Contact
(Alarm)

Power Distances and Supplies

Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Note
Unshielded Twisted Pair (UTP) is a general term for all cabling systems used
for transmission of data and providing connectivity on a network via a UTP
cable. A UTP cable can contain multiple pairs of twisted cables. Commonly
used for telephone cabling and 10BaseT and 100BaseT networks using
CAT5, CAT5E, CAT6 cables.
See
Table 2-1
for the recommended cables and maximum distances for proper operation
of the dome. Where applicable, use Category 5 (CAT5) cables or higher.
Table 2-1
Recommended Cables and Maximum Distances
Recommended Cable
18 AWG 2-conductor
Coaxial cable - RG59/U
Connector - BNC crimp on for RG59/U
CAT5 or better
1 twisted pair for data
1 twisted pair for video
One shielded twisted pair, RS485 cable, can also
be UTP CAT5 or better
20 gauge unshielded twisted pair
The indoor ACUIX requires a 24 VAC power supply at 1.9A, measured at the dome. The
outdoor ACUIX requires a 24 VAC power supply at 2.5A, also measured at the dome.
Note
For optimum ACUIX performance, use a dedicated 24V 100 VA transformer
wherever possible.
See the following tables to determine the wire sizes and maximum distances for one
power source for one ACUIX and the required power supplies for CE compliance.
Maximum Distance
See gauge chart for each unit
1000 feet (305 meters)
1200 feet (366 meters)
4000 feet (1219 meters)
10,000 feet (3048 meters)