Installing the Indoor and Outdoor Pendant Housing
Installing the Rugged Housing
Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
Figure 3-16
Indoor Pendant Housing
1.
If not already done, route the field wiring:
•
Through the housing mount, then
•
Through the field wiring access hole in the housing, and then
•
Through the access hole in the interface board installed in the housing.
Note
The wiring must extend at least one foot (0.3 m) past the mount for wiring
purposes.
2.
Install the housing on the mount. Make sure there is Teflon
nipple part of the housing.
Figure 3-17
Rugged Housing and Bracket
Field wiring
access hole
1.
Complete the bracket installation as described previously.
2.
If not already done, route the field wiring:
a.
Through the field wiring access hole in the housing, and
b.
Through the access hole in the interface board installed in the housing.
3.
Install a 0.75"(19 mm) conduit fitting in the hole on the housing.
Threaded nipple
®
tape on the threaded