Restoring Default Settings Or Resetting The Dome Or Lens; Restoring Defaults Using The Osd; Restoring To Factory Defaults Using A Switch - Honeywell ACUIX Installation And Configuration Manual

Ptz high speed analog dome camera
Hide thumbs Also See for ACUIX:
Table of Contents

Advertisement

Restoring Default Settings or Resetting the Dome or Lens

Restoring Defaults Using the OSD

Restoring to Factory Defaults Using a Switch

Document 800-05662 Rev C
06/10
ACUIX™ PTZ High Speed Analog Dome Installation and Configuration Guide
There are two types of factory defaults that can be restored either directly on the dome via
the OSD Diagnostic Options menu or using a DIP switch. There is an important distinction
between the two.
Using the OSD menu restores all of the camera and dome configuration settings to
the factory defaults, but DOES NOT delete user programmed configurations (presets,
preset tours, mimic tours, sectors and privacy zones).
Using DIP switch SW5-7 restores all the settings to defaults and DOES delete user
programmed configurations (presets, preset tours, mimic tours, sectors and privacy
zones).
1.
Select 4 Diagnostic Options
2.
Select:
N to cancel.
Y to continue.
This will restore all user default settings to their default
values displays.
Note
The switch is read only at power up.
1.
Locate switch SW5-7.
2.
Carefully place the switch in the required position.
(Default) Select OFF to keep normal operation.
Select ON to restore factory default settings and delete any user programmed
configurations (presets, preset tours, mimic tours, sectors and privacy zones).
3.
After the factory default is restored, set switch back to OFF position to prevent
unwanted deletion of user programmed configurations.
6 Restore Default Settings.
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents